MEMBRANE TECHNOLOGY FOR WATERjohnny@minipore.com
MURFILTEC
MODEL / UF

HM4046 / HM90

Inside-out ultrafiltration

MODEL INFORMATION

Technical specifications.

Source-table values are provided for initial comparison. Confirm current specifications and suitability before design or ordering.

Enquire about this model ↗
Design flux · L/(m²·h)
40–80
Membrane material
PVC / PAN
Fiber inner / outer diameter · mm
1.0 / 1.6 mm
Membrane area · m²
4.5
Maximum feed pressure · MPa
0.30
Maximum TMP · MPa
<0.20
Recommended operating differential pressure · MPa
0.01–0.10

Conditions & notes

Fiber dimensions
Inner / outer diameter values use mm as explicitly written in source cells; the website column heading incorrectly says μm.
Alias convention
Each slash-separated designation is one configuration. Material choices do not create extra model rows.
Permeate SDI₁₅
<3
Expected filtrate turbidity
<1 NTU

Published source-table values; performance varies with feed water and operating conditions. Confirm the current model-specific data sheet before design.

Representative membrane construction detail
Representative category image, not a photograph identifying this specific model.
LET'S TALK WATER

Start with the right questions.

Tell us about your feed water, process and performance requirements.

Discuss your project ↗