MODEL / UF
HM2880 / FRT-UF2880
Outside-in ultrafiltration
MODEL INFORMATION
Technical specifications.
Source-table values are provided for initial comparison. Confirm current specifications and suitability before design or ordering.
Enquire about this model ↗- Design flux · L/(m²·h)
- 40–80
- Membrane material
- PVDF
- Fiber inner / outer diameter · mm
- 0.7 / 1.3 mm
- Membrane area · m²
- 77
- Maximum feed pressure · MPa
- ≤0.30
- Maximum TMP · MPa
- 0.20
- Recommended operating differential pressure · MPa
- ≤0.15
Conditions & notes
- Fiber dimensions
- Inner / outer diameter values use mm as explicitly written in source cells; the website column heading incorrectly says μm.
- Alias convention
- Each slash-separated designation is one configuration. Material choices do not create extra model rows.
Published source-table values; performance varies with feed water and operating conditions. Confirm the current model-specific data sheet before design. PVDF follows the detailed model table; the conflicting PVC / PAN summary is not applied to these modules.

LET'S TALK WATER
Start with the right questions.
Tell us about your feed water, process and performance requirements.