MEMBRANE SEPARATION & WATER PURIFICATION johnny@minipore.com ↗
Representative product photo; appearance and dimensions vary by model.
Representative product photo; appearance and dimensions vary by model.

UF / SERIES OVERVIEW

Outside-in ultrafiltration

Two PVDF configurations: HM2860 / FRT-UF2860 and HM2880 / FRT-UF2880.

APPLICATION FIT

Pretreatment & clarification

TECHNOLOGY IN CONTEXT

A precise fit for your water process.

A porous hollow-fiber barrier separates particles and colloids. Backwashing and cleaning are part of operation.

Discuss your requirements

  • Feed-water analysis and pretreatment
  • Model-specific flow and operating conditions
  • Dimensions, materials and system compatibility

INDIVIDUAL PRODUCTS

Choose your model.

PRODUCT INFORMATION

Configuration at a glance

Series
Outside-in
Filtration direction
Outside-in
Membrane material
PVDF

MODEL CONFIGURATIONS

Model specifications

Official website model table · Published source-table values; performance varies with feed water and operating conditions. Confirm the current model-specific data sheet before design. PVDF follows the detailed model table; the conflicting PVC / PAN summary is not applied to these modules.

HM2860 / FRT-UF2860 View specifications +
Design flux · L/(m²·h)
40–80
Membrane material
PVDF
Fiber inner / outer diameter · mm
0.7 / 1.3 mm
Membrane area · m²
51
Maximum feed pressure · MPa
≤0.30
Maximum TMP · MPa
0.20
Recommended operating differential pressure · MPa
≤0.15
HM2880 / FRT-UF2880 View specifications +
Design flux · L/(m²·h)
40–80
Membrane material
PVDF
Fiber inner / outer diameter · mm
0.7 / 1.3 mm
Membrane area · m²
77
Maximum feed pressure · MPa
≤0.30
Maximum TMP · MPa
0.20
Recommended operating differential pressure · MPa
≤0.15

Test conditions & reference basis

Fiber dimensions
Inner / outer diameter values use mm as explicitly written in source cells; the website column heading incorrectly says μm.
Alias convention
Each slash-separated designation is one configuration. Material choices do not create extra model rows.

Specify with confidence.

Confirm the exact model, current data-sheet revision, feed-water limits and test conditions before finalizing your design. The published specifications follow the designated source for this series; no legacy-only model variants are combined into this table.

Ask for the current data sheet