MODEL / EDI
KXA-50
KXA standard EDI modules
MODEL INFORMATION
Technical specifications.
Source-table values are provided for initial comparison. Confirm current specifications and suitability before design or ordering.
Enquire about this model ↗- Standard product-water flow
- 500 L/H
- Product-water flow range
- 0.3-0.7 m³/h
- Current
- 1-6 A DC
- Voltage (source unit unspecified)
- 0-400 (unit not specified in source)
- Recovery · %
- 90-95
- Product-water resistivity
- 15-18.25 MΩ·cm
- Mounting-foot spacing
- 170 × 217 mm
- Overall dimensions
- 270 × 320 × 605 mm
- Diluate-water connectors
- DN32 male thread
- Concentrate-water connectors
- DN20 male thread
Conditions & notes
- Feed basis
- Brochure physical p7 contains general feed requirements, not individual model test certificates. Model-specific test temperature is not listed.
- Feed temperature
- 5–35°C; preferred 25°C (general brochure requirement, not a model test temperature)
- Feed pressure
- 1.5–5.0 bar
- Normal-flow pressure drop
- 1.4–2.1 bar
- Feed pH
- 6.5–9.0
- Feed conductivity
- 1–10 μS/cm; second-pass RO permeate
- CO₂
- <5 ppm
- Total hardness
- <0.5 ppm; conversion basis not specified
- Reactive silica
- ≤0.5 ppm; preferred ≤0.2 ppm
- TOC
- ≤0.5 ppm
- Residual chlorine
- ≤0.03 ppm
- Fe / Mn
- ≤0.01 ppm
- Electrical basis
- Current is DC. The voltage table does not print a unit; no voltage unit is inferred.
Published source-table values; performance varies with feed water and operating conditions. Confirm the current model-specific data sheet before design. Identities and specifications follow the supplied module brochure parameter tables, not photographed KLX labels.

LET'S TALK WATER
Start with the right questions.
Tell us about your feed water, process and performance requirements.