Module brochure parameter table · Published source-table values; performance varies with feed water and operating conditions. Confirm the current model-specific data sheet before design. Identities and specifications follow the supplied module brochure parameter tables, not photographed KLX labels.
KXA-50 View specifications +
Standard product-water flow
500 L/H
Product-water flow range
0.3-0.7 m³/h
Current
1-6 A DC
Voltage (source unit unspecified)
0-400 (unit not specified in source)
Recovery · %
90-95
Product-water resistivity
15-18.25 MΩ·cm
Mounting-foot spacing
170 × 217 mm
Overall dimensions
270 × 320 × 605 mm
Diluate-water connectors
DN32 male thread
Concentrate-water connectors
DN20 male thread
KXA-100 View specifications +
Standard product-water flow
1000 L/H
Product-water flow range
0.5-1.4 m³/h
Current
1-6 A DC
Voltage (source unit unspecified)
0-400 (unit not specified in source)
Recovery · %
90-95
Product-water resistivity
15-18.25 MΩ·cm
Mounting-foot spacing
243 × 217 mm
Overall dimensions
345 × 320 × 605 mm
Diluate-water connectors
DN32 male thread
Concentrate-water connectors
DN20 male thread
KXA-200 View specifications +
Standard product-water flow
2000 L/H
Product-water flow range
1.5-2.5 m³/h
Current
1-6 A DC
Voltage (source unit unspecified)
0-400 (unit not specified in source)
Recovery · %
90-95
Product-water resistivity
15-18.25 MΩ·cm
Mounting-foot spacing
388 × 217 mm
Overall dimensions
500 × 320 × 605 mm
Diluate-water connectors
DN32 male thread
Concentrate-water connectors
DN20 male thread
KXA-300 View specifications +
Standard product-water flow
3000 L/H
Product-water flow range
2.5-3.5 m³/h
Current
1-6 A DC
Voltage (source unit unspecified)
0-400 (unit not specified in source)
Recovery · %
90-95
Product-water resistivity
15-18.25 MΩ·cm
Mounting-foot spacing
535 × 217 mm
Overall dimensions
660 × 320 × 605 mm
Diluate-water connectors
DN32 male thread
Concentrate-water connectors
DN20 male thread
KXA-400 View specifications +
Standard product-water flow
4000 L/H
Product-water flow range
3-4.5 m³/h
Current
1-6 A DC
Voltage (source unit unspecified)
0-400 (unit not specified in source)
Recovery · %
90-95
Product-water resistivity
15-18.25 MΩ·cm
Mounting-foot spacing
680 × 217 mm
Overall dimensions
820 × 320 × 605 mm
Diluate-water connectors
DN32 male thread
Concentrate-water connectors
DN20 male thread
KXA-500 View specifications +
Standard product-water flow
5000 L/H
Product-water flow range
5-7.8 m³/h
Current
1-6 A DC
Voltage (source unit unspecified)
0-400 (unit not specified in source)
Recovery · %
90-95
Product-water resistivity
15-18.25 MΩ·cm
Mounting-foot spacing
755 × 217 mm
Overall dimensions
930 × 320 × 605 mm
Diluate-water connectors
DN32 male thread
Concentrate-water connectors
DN20 male thread
KXA-600 View specifications +
Standard product-water flow
6000 L/H
Product-water flow range
6-8.5 m³/h
Current
1-6 A DC
Voltage (source unit unspecified)
0-500 (unit not specified in source)
Recovery · %
90-95
Product-water resistivity
15-18.25 MΩ·cm
Mounting-foot spacing
968 × 217 mm
Overall dimensions
1140 × 320 × 605 mm
Diluate-water connectors
DN32 male thread
Concentrate-water connectors
DN20 male thread
KXA-700 View specifications +
Standard product-water flow
7000 L/H
Product-water flow range
7.5-9.5 m³/h
Current
1-6 A DC
Voltage (source unit unspecified)
0-500 (unit not specified in source)
Recovery · %
90-95
Product-water resistivity
15-18.25 MΩ·cm
Mounting-foot spacing
1041 × 217 mm
Overall dimensions
1223 × 320 × 605 mm
Diluate-water connectors
DN32 male thread
Concentrate-water connectors
DN20 male thread
Test conditions & reference basis
Feed basis
Brochure physical p7 contains general feed requirements, not individual model test certificates. Model-specific test temperature is not listed.
Feed temperature
5–35°C; preferred 25°C (general brochure requirement, not a model test temperature)
Feed pressure
1.5–5.0 bar
Normal-flow pressure drop
1.4–2.1 bar
Feed pH
6.5–9.0
Feed conductivity
1–10 μS/cm; second-pass RO permeate
CO₂
<5 ppm
Total hardness
<0.5 ppm; conversion basis not specified
Reactive silica
≤0.5 ppm; preferred ≤0.2 ppm
TOC
≤0.5 ppm
Residual chlorine
≤0.03 ppm
Fe / Mn
≤0.01 ppm
Electrical basis
Current is DC. The voltage table does not print a unit; no voltage unit is inferred.
Specify with confidence.
Confirm the exact model, current data-sheet revision, feed-water limits and test conditions before finalizing your design. The published specifications follow the designated source for this series; no legacy-only model variants are combined into this table.