MEMBRANE SEPARATION & WATER PURIFICATION johnny@minipore.com ↗
Representative product photo; appearance and dimensions vary by model.
Representative product photo; appearance and dimensions vary by model.

Residential RO / SERIES OVERVIEW

LP residential RO

Residential LP elements for feed water of 500 < PPM < 2000.

APPLICATION FIT

Residential & compact commercial water

TECHNOLOGY IN CONTEXT

A precise fit for your water process.

Pressure drives water through a reverse osmosis element to reduce dissolved salts. Match the element to the feed water, housing and flow.

Discuss your requirements

  • Feed-water analysis and pretreatment
  • Model-specific flow and operating conditions
  • Dimensions, materials and system compatibility

INDIVIDUAL PRODUCTS

Choose your model.

PRODUCT INFORMATION

Configuration at a glance

Series
LP
Feed salinity
500 < PPM < 2000

MODEL CONFIGURATIONS

Model specifications

Official website model table · Published source-table values; performance varies with feed water and operating conditions. Confirm the current model-specific data sheet before design.

LP1812-50 View specifications +
Average permeate flow · GPD
50
Test pressure / recovery
60 psi / 50%
Salt rejection · % (residential: as stated)
96%
A · element length · mm
298
B · element diameter · mm
45
C · element tube diameter · mm
17
D1 · element end diameter · mm
21
D2 · element end spacing · mm
21
LP1812-75 View specifications +
Average permeate flow · GPD
75
Test pressure / recovery
60 psi / 50%
Salt rejection · % (residential: as stated)
96%
A · element length · mm
298
B · element diameter · mm
45
C · element tube diameter · mm
17
D1 · element end diameter · mm
21
D2 · element end spacing · mm
21
LP2012-100 View specifications +
Average permeate flow · GPD
100
Test pressure / recovery
60 psi / 50%
Salt rejection · % (residential: as stated)
96%
A · element length · mm
298
B · element diameter · mm
47
C · element tube diameter · mm
17
D1 · element end diameter · mm
21
D2 · element end spacing · mm
21
LP2012-125 View specifications +
Average permeate flow · GPD
125
Test pressure / recovery
60 psi / 50%
Salt rejection · % (residential: as stated)
96%
A · element length · mm
298
B · element diameter · mm
47
C · element tube diameter · mm
17
D1 · element end diameter · mm
21
D2 · element end spacing · mm
21
LP2012-150 View specifications +
Average permeate flow · GPD
150
Test pressure / recovery
60 psi / 50%
Salt rejection · % (residential: as stated)
96%
A · element length · mm
298
B · element diameter · mm
47
C · element tube diameter · mm
17
D1 · element end diameter · mm
21
D2 · element end spacing · mm
21
LP2012-200 View specifications +
Average permeate flow · GPD
200
Test pressure / recovery
60 psi / 50%
Salt rejection · % (residential: as stated)
96%
A · element length · mm
298
B · element diameter · mm
47
C · element tube diameter · mm
17
D1 · element end diameter · mm
21
D2 · element end spacing · mm
21
LP2812-200 View specifications +
Average permeate flow · GPD
200
Test pressure / recovery
60 psi / 50%
Salt rejection · % (residential: as stated)
96%
A · element length · mm
298
B · element diameter · mm
67.8
C · element tube diameter · mm
17
D1 · element end diameter · mm
21
D2 · element end spacing · mm
21
LP3012-300 View specifications +
Average permeate flow · GPD
300
Test pressure / recovery
80 psi / 50%
Salt rejection · % (residential: as stated)
96%
A · element length · mm
298
B · element diameter · mm
73
C · element tube diameter · mm
17
D1 · element end diameter · mm
21
D2 · element end spacing · mm
21
LP3012-400 View specifications +
Average permeate flow · GPD
400
Test pressure / recovery
80 psi / 50%
Salt rejection · % (residential: as stated)
96%
A · element length · mm
298
B · element diameter · mm
73
C · element tube diameter · mm
17
D1 · element end diameter · mm
21
D2 · element end spacing · mm
21
LP3013-400 View specifications +
Average permeate flow · GPD
400
Test pressure / recovery
80 psi / 50%
Salt rejection · % (residential: as stated)
96%
A · element length · mm
333
B · element diameter · mm
67.8
C · element tube diameter · mm
17
D1 · element end diameter · mm
21
D2 · element end spacing · mm
21
LP3012-500 View specifications +
Average permeate flow · GPD
500
Test pressure / recovery
80 psi / 50%
Salt rejection · % (residential: as stated)
96%
A · element length · mm
298
B · element diameter · mm
73
C · element tube diameter · mm
17
D1 · element end diameter · mm
21
D2 · element end spacing · mm
21
LP3012-600 View specifications +
Average permeate flow · GPD
600
Test pressure / recovery
80 psi / 50%
Salt rejection · % (residential: as stated)
96%
A · element length · mm
298
B · element diameter · mm
73
C · element tube diameter · mm
17
D1 · element end diameter · mm
21
D2 · element end spacing · mm
21
LP3013-600 View specifications +
Average permeate flow · GPD
600
Test pressure / recovery
80 psi / 50%
Salt rejection · % (residential: as stated)
96%
A · element length · mm
333
B · element diameter · mm
67.8
C · element tube diameter · mm
17
D1 · element end diameter · mm
21
D2 · element end spacing · mm
21
LP3012-800 View specifications +
Average permeate flow · GPD
800
Test pressure / recovery
80 psi / 50%
Salt rejection · % (residential: as stated)
96%
A · element length · mm
298
B · element diameter · mm
73
C · element tube diameter · mm
17
D1 · element end diameter · mm
21
D2 · element end spacing · mm
21
LP3013-800 View specifications +
Average permeate flow · GPD
800
Test pressure / recovery
80 psi / 50%
Salt rejection · % (residential: as stated)
96%
A · element length · mm
333
B · element diameter · mm
67.8
C · element tube diameter · mm
17
D1 · element end diameter · mm
21
D2 · element end spacing · mm
21
LP3213-800 View specifications +
Average permeate flow · GPD
800
Test pressure / recovery
80 psi / 50%
Salt rejection · % (residential: as stated)
96%
A · element length · mm
333
B · element diameter · mm
78
C · element tube diameter · mm
17
D1 · element end diameter · mm
21
D2 · element end spacing · mm
21
LP3213-1000 View specifications +
Average permeate flow · GPD
1000
Test pressure / recovery
80 psi / 50%
Salt rejection · % (residential: as stated)
96%
A · element length · mm
333
B · element diameter · mm
83
C · element tube diameter · mm
17
D1 · element end diameter · mm
21
D2 · element end spacing · mm
21

Test conditions & reference basis

Dimensions
All A / B / C / D1 / D2 values are in mm. A: element length; B: element diameter; C: element tube diameter; D1: element end diameter; D2: element end spacing (source terminology).
Flow basis
Average permeate flow in GPD, not industrial GPD (m³/d). Pressure and recovery are model-specific.

Specify with confidence.

Confirm the exact model, current data-sheet revision, feed-water limits and test conditions before finalizing your design. The published specifications follow the designated source for this series; no legacy-only model variants are combined into this table.

Ask for the current data sheet

LET’S DEFINE THE RIGHT FIT

Your water. Your process.
A clearer starting point.

Tell us about your feed water and the quality you need.

Talk to us