MEMBRANE SEPARATION & WATER PURIFICATION johnny@minipore.com ↗
Representative EDI module photo; appearance and dimensions vary by model.
Representative EDI module photo; appearance and dimensions vary by model.

EDI / SERIES OVERVIEW

KXGW EDI modules

KXGW electrodeionization modules for continuous polishing of suitably pretreated RO permeate.

APPLICATION FIT

RO permeate polishing

TECHNOLOGY IN CONTEXT

A precise fit for your water process.

Ions migrate through selective membranes under a DC field. Ion-exchange media support continuous polishing of suitably pretreated RO permeate.

Discuss your requirements

  • Feed-water analysis and pretreatment
  • Model-specific flow and operating conditions
  • Dimensions, materials and system compatibility

INDIVIDUAL PRODUCTS

Choose your model.

PRODUCT INFORMATION

Configuration at a glance

Series
KXGW
Process position
RO permeate polishing

MODEL CONFIGURATIONS

Model specifications

Module brochure parameter table · Published source-table values; performance varies with feed water and operating conditions. Confirm the current model-specific data sheet before design. Identities and specifications follow the supplied module brochure parameter tables, not photographed KLX labels.

KXGW-50 View specifications +
Standard product-water flow
0.5 m³/h
Product-water flow range
0.3-0.7 m³/h
Current
1-6 A DC
Voltage (source unit unspecified)
0-400 (unit not specified in source)
Recovery · %
90-95
Product-water resistivity
15-18.25 MΩ·cm
Mounting-foot spacing
216 × 200 mm
Overall dimensions
324 × 312 × 605 mm
Diluate-water connectors
DN32 female thread
Concentrate-water connectors
DN20 female thread
KXGW-100 View specifications +
Standard product-water flow
1 m³/h
Product-water flow range
0.7-1.5 m³/h
Current
1-6 A DC
Voltage (source unit unspecified)
0-400 (unit not specified in source)
Recovery · %
90-95
Product-water resistivity
15-18.25 MΩ·cm
Mounting-foot spacing
288 × 200 mm
Overall dimensions
395 × 312 × 605 mm
Diluate-water connectors
DN32 female thread
Concentrate-water connectors
DN20 female thread
KXGW-200 View specifications +
Standard product-water flow
2 m³/h
Product-water flow range
1.5-2.5 m³/h
Current
1-6 A DC
Voltage (source unit unspecified)
0-400 (unit not specified in source)
Recovery · %
90-95
Product-water resistivity
15-18.25 MΩ·cm
Mounting-foot spacing
440 × 200 mm
Overall dimensions
547 × 312 × 605 mm
Diluate-water connectors
DN32 female thread
Concentrate-water connectors
DN20 female thread
KXGW-300 View specifications +
Standard product-water flow
3 m³/h
Product-water flow range
2.5-3.5 m³/h
Current
1-6 A DC
Voltage (source unit unspecified)
0-400 (unit not specified in source)
Recovery · %
90-95
Product-water resistivity
15-18.25 MΩ·cm
Mounting-foot spacing
592 × 200 mm
Overall dimensions
699 × 312 × 605 mm
Diluate-water connectors
DN32 female thread
Concentrate-water connectors
DN20 female thread
KXGW-400 View specifications +
Standard product-water flow
4 m³/h
Product-water flow range
3-4.5 m³/h
Current
1-6 A DC
Voltage (source unit unspecified)
0-400 (unit not specified in source)
Recovery · %
90-95
Product-water resistivity
15-18.25 MΩ·cm
Mounting-foot spacing
744 × 200 mm
Overall dimensions
851 × 312 × 605 mm
Diluate-water connectors
DN32 female thread
Concentrate-water connectors
DN20 female thread
KXGW-500 View specifications +
Standard product-water flow
5 m³/h
Product-water flow range
4-5.5 m³/h
Current
1-6 A DC
Voltage (source unit unspecified)
0-400 (unit not specified in source)
Recovery · %
90-95
Product-water resistivity
15-18.25 MΩ·cm
Mounting-foot spacing
815 × 200 mm
Overall dimensions
922 × 312 × 605 mm
Diluate-water connectors
DN32 female thread
Concentrate-water connectors
DN20 female thread

Test conditions & reference basis

Feed basis
Brochure physical p7 contains general feed requirements, not individual model test certificates. Model-specific test temperature is not listed.
Feed temperature
5–35°C; preferred 25°C (general brochure requirement, not a model test temperature)
Feed pressure
1.5–5.0 bar
Normal-flow pressure drop
1.4–2.1 bar
Feed pH
6.5–9.0
Feed conductivity
1–10 μS/cm; second-pass RO permeate
CO₂
<5 ppm
Total hardness
<0.5 ppm; conversion basis not specified
Reactive silica
≤0.5 ppm; preferred ≤0.2 ppm
TOC
≤0.5 ppm
Residual chlorine
≤0.03 ppm
Fe / Mn
≤0.01 ppm
Electrical basis
Current is DC. The voltage table does not print a unit; no voltage unit is inferred.
Thermal disinfection
85±5°C, ≤0.2 MPa, >150 cycles. These are disinfection conditions, not continuous operating temperature.

Specify with confidence.

Confirm the exact model, current data-sheet revision, feed-water limits and test conditions before finalizing your design. The published specifications follow the designated source for this series; no legacy-only model variants are combined into this table.

Ask for the current data sheet

PROCESS PRINCIPLE

Continuous polishing after RO.

Conceptual electrodeionization working principle diagram

Generic EDI principle. Not a model-specific performance or electrical specification.

Continue exploring.

All EDI products →

LET’S DEFINE THE RIGHT FIT

Your water. Your process.
A clearer starting point.

Tell us about your feed water and the quality you need.

Talk to us